Availability: | |
---|---|
Quantity: | |
CHAIN FD 430 CY
zhaolong
TECHNICAL PARAMETERS
—Temperature Range
Fixed Application: -40°C~70°C
Mobile Application: -5°C~70°C
—Test Voltage
4000V/min(AC)
—Insulation Resistance(20°C)
≥20MΩ.km
—Rated Voltage
300/500V
—Minimum Bending Radius
Fixed Application: 4D(D=cable diameter)
Mobile Application: 7.5D(D=cable diameter)
—Technical Certification:
UL2464
—Application of drag chain
3~10milliontimes
CABLE CONSTRUCTIONP
Conductor:
Fine stranded bare copper, according to IEC 60228/VDE 0295 class 6
Insulation:
TPE
Insulation Color:
According to DIN VDE 0293, black cores with white numbering, green-yellow conductor
Shielded:
Tinned copper braiding
Jacket:
PVC
Color:
Grey(similar to RAL7001)
ROPERTIES
Flame resistance according to IEC 60332-1
Good flexibility
Small bending radius
Conditional oil resistance
Excellent resistance to external EMI
TECHNICAL PARAMETERS
—Temperature Range
Fixed Application: -40°C~70°C
Mobile Application: -5°C~70°C
—Test Voltage
4000V/min(AC)
—Insulation Resistance(20°C)
≥20MΩ.km
—Rated Voltage
300/500V
—Minimum Bending Radius
Fixed Application: 4D(D=cable diameter)
Mobile Application: 7.5D(D=cable diameter)
—Technical Certification:
UL2464
—Application of drag chain
3~10milliontimes
CABLE CONSTRUCTIONP
Conductor:
Fine stranded bare copper, according to IEC 60228/VDE 0295 class 6
Insulation:
TPE
Insulation Color:
According to DIN VDE 0293, black cores with white numbering, green-yellow conductor
Shielded:
Tinned copper braiding
Jacket:
PVC
Color:
Grey(similar to RAL7001)
ROPERTIES
Flame resistance according to IEC 60332-1
Good flexibility
Small bending radius
Conditional oil resistance
Excellent resistance to external EMI
content is empty!
2020-07-20 171
Getting to Know the Generic Cabling in Industrial Environments